Why lithium?
High quality 12 V Lithium Iron Phosphate (LiFePO4) cells are the basis for WhisperPower’s new lithium storage systems. The new lithium Power Plus Battery Racks are a sustainable and highly energy dense solution to store electrical energy for use “on demand”. Due to the specific characteristics of the Whis- perPower LFP ferro lithium batteries, the battery pack(s) can be charged and discharged at high amperes.
The added value of WhisperPower
All Lithium battery solutions can be supplied just “as a bat- tery”. However, we offer our customers a total solution that eliminates the risk of the user’s battery not being charged, discharged or monitored properly. The system approach goes beyond simply supplying a WhisperPower battery charger or combination inverter/charger. If required, we can supply a complete diesel fuel based fast charge system in combination with the Lithium Power Plus rack with integrated BMS, DC bus bar (s) distribution including fuses and an advanced monitor- ing system that monitors the behavior of the cells inside the battery down to the cell level: WhisperCare.
Sustainable and cleaner for the user
Further electrification to replace or supplement fossil power solutions reduces the carbon footprint on a substantial basis. In addition, large cost savings can be achieved because the fossil power system can be used much more efficiently.
A higher upfront investment is recouped within a short time.
Lithium Power Plus modular battery rack system
Added Value Services from WhisperPower
TECHNICAL SPECIFICATIONS | |
Chemistry | LiFePO4 |
Module configuration (12 V module) | 4s3p |
Number of modules | 12 |
Nominal voltage | 48 V |
Open circuit voltage | 52,8 V |
Nominal capacity | 315 Ah |
Nominal energy | 22,2 kWh |
Cycle Life DOD 80% | >3500 cycles (at 1C charge / discharge, 80% DoD |
Self discharge | <3% per month |
Weight modules (excel. aluminum cabinet), kg (lb) | 120 (264.6) |
CHARGE PARAMETERS | |
Charge method | CCCV |
Maximum charge voltage | 59,6 V |
Recommended charge voltage | 57,2 V |
Recommended charge current | 157.5 A (0.5 C) |
Continuous charge current | 315 A (1.0 C) |
DISCHARGE PARAMETERS | |
Discharge cut-off voltage | 43,2 V |
Recommended discharge current | 157 A (0.5C) |
Maximum discharge current | 315 A (1.0C) |
Discharge pulse current | 630 A (2C 10 sec, SOC >60%) |
Fuse protection | 3*225 A T-class |
MECHANICAL | |
Power connections | M10 stud, max 20NM |
Cable connections | Option: Top or Bottom |
IP-Protection class | IP 66 cell IP20 connection |
Cooling | Natural air convection |
Module material | PC-ABS, UL94-V0 |
Battery case material | Aluminium Powdercoat |
Dimensions (l x w x h), mm | 1260 x 280 x 465 (540) |
Dimensions (l x w x h), inches | 49,6 x 11 x 18,3 (21,3”) |
Total weight module plus cabinet | ±150-160 kg / 331-353 lbs |
CONFIGURATION | |
Series configuration | No |
Parallel configuration | No |
Redundant mode | Yes, using double BIM |
ENVIRONMENTAL | |
Operating temperature charge | 0°C to 55 °C / 32°F to 131°F |
Operating temperature discharge | -20°C to 55°C / -4°F to 131°F |
Storage temperature | -20°C to 45°C / -4°F to 113°F |
Humidity (Non-condensing) | <95% |
SAFETY | |
Battery Management System (BMS) | External WP-BIM module |
Balancing | Passive method |
Communication CAN-Bus | whisperconnect/NMEA2000 |
EMC: Emission | EN-IEC 61000-6-3:2007/A1:2011/C11:2012 |
EMC: Immunity | EN-IEC 61000-6-1:2007 |
Low voltage directive | EN 60335-1:2012/AC:2014 |
Certifications | CE, FCC, UN 38.3, UL 1642 (Cells), UN ECE R10.06, EN/IEC 62620(ESTRIN) |
Shipping classification | UN3480 |