Kraken Charging Hub

-3000W/100A/50A 12V/100Ah-bak

Descriptions

KEEPING TOOLS CHARGED IS A CHALLENGE

  • MORE ELECTRIFICATION MEANS MORE BATTERIES, MORE CHARGERS.
  • ELECTRICAL LOAD REQUIREMENTS ARE NOT CONSIDERED WHEN BUYING TOOLS.
    • MOST TOOL MANUFACTURERS DO NOT EVEN PUBLISH REQUIRED INPUT POWER (WATTS).
  • SHORE POWER IS LIMITED.
  • TOOL UPGRADES TO BATTERY POWER SHOULD INCLUDE APPARATUS ELECTRICAL SYSTEM UPGRADE.

WHAT’S THE POINT?

  • MOST BATTERY TOOLS ARE PLUGGED INTO AC OUTLETS WHICH ARE ONLY LIVE WHEN APPARATUS IS PLUGGED I NTO SHORE POWER.
    • DEPARTMENTS OFTEN HAVE <1 HOUR OF “CHARGE TIME” BETWEEN CALLS
    • COMMON BATTERY PACKS IN FIRE SERVICE REQUIRE >3 HOURS TO CHARGE
    • MAINTAINING FULL CHARGE OF ALL PACKS IS INCREASINGLY DIFFICULT AS MORE BATTERY TOOLS ARE ACQUIRED.
  • INSTEAD OF LIMITING TOOL RECHARGE TO SHORT IN-STATION TIME, SETUP CONTINUOUS ONBOARD AC TO SPREAD LOAD THROUGHOUT DAY.

WHY APPARATUS CAN’T PROVIDE ENOUGH CHARGING POWER

Most fire apparatus are built with low-voltage electrical systems (12V) to power basic equipment (i.e. lights, low power chargers).

As more battery tools are acquired, the apparatus electrical system must be capable of charging tool batteries fast enough to stay fully charged and in service.

 

 

WHAT IS A KRAKEN POWER CHARGING HUB?

  • CHARGING HUBS PROVIDE CONTINUOUS ONBOARD AC POWER, INSTEAD OF TRYING TO CHARGE EVERYTHING IN THE SHORT TIME THE APPARATUS IS PLUGGED INTO SHORE POWER.
    • BATTERY TOOL CHARGING HUBS HELP TO SPREAD THE LOAD OF TOOL CHARGING OVER TIME, STARTING WHEN THE DEPLETED BATTERY IS PLACED ON ITS CHARGER.
  • STORE ENERGY AND TAKE IT WITH YOU.
    • CHARGE TOOL BATTERIES CONTINUOUSLY, FROM INVERTER AND LITHIUM BATTERY BANK.
      DEDICATE SHORE POWER TO RECHARGING TRUCK BATTERIES.

Specifications

 

DIMENSIONS & WEIGHT
Weight (Kg) 0.8
Enclosure width (in) 3.75
Enclosure height (in) 5.74
Enclouser depth (in) 2.02
GENERAL
Ambient operation temperature -4°F … +104°F
Storage temperature -13°F … +185°F
Operating humidity 95%, non condens
Live current switching 100.000 cyles
MECHANICAL
Connections terminal stud M10 (3/8”-.16)
Connections stud length (in) 0.90
Maximum terminal Stud Torque 15.5 NM (140 in-lb)
Terminal material tin-plated copper
Drilling mounting centers (in) 4.5 x 3
Mounting screws (in) 0.15
Ingress Protection Class IP66
Enclouser Colour RAL9011 Graphite Black
Calbe clearance (in) 1.12
Ignition Protection SA J1171
Markings CE, Iso 8846
INPUT
Battery input 2
Switch Positions 2
Manual overide Locked off/on
I 10 Cranking rating 10 sec 2500A
I 60 Cranking rating 1 min 1100A
I 300 Cintermittent rating 5 min 700A
I C continue rating 500A
Vmno Voltage maxium Operation 32V DC
Control Circuit Voltage 10.1..16.5VDC
Operation current continuous < 40mA
Operation current when charging <7A

Remote Control switch when charging

100mA
Automatically combines battery banks when sensed voltage levels are:

Above 13.5 for 30 sec. Above 13.0 for 90 sec.

Automatically isolates battery banks when sensed voltage levels are:

Below 9.6V (undervoltage lockout) Below 12.35V for 10 sec. Below 12.75V for 30 sec. Above 16.2V (undervoltage lockout)

 